IP TELEVISION SYSTEM (IP TV) - Mr.CON.

Mr.CON.

project management&development of factories

Breaking News

Thursday, 12 January 2012

IP TELEVISION SYSTEM (IP TV)

IP TELEVISION SYSTEM (IP TV)
Page
PART 1 GENERAL 2
1.1 Related Documents 2
1.2 Description of Work 2
1.3 Reference Codes and Standards 2
1.4 Submittals 3
1.5 Quality Assurance 4
1.6 Delivery, Storage and Handling 4
1.7 Related Sections 4
1.8 As-Built Drawings 4
PART 2 PRODUCTS 5
2.1 General 5
2.2 Equipment and Materials 5
2.3 System Features 6
PART 3 EXECUTION 12
3.1 Examination 12
3.2 Installation of Basic Identification 12
3.3 Installation of Basic Wiring System Materials 12
3.4 Installation of Television Distribution System 12
3.5 Field Quality Control 14
2
SECTION 16785
IP TELEVISION SYSTEM (IP TV)
PART 1 GENERAL
1.1 RELATED DOCUMENTS
Drawings and general provisions of the Contract.
1.2 DESCRIPTION OF WORK
IP TV (Internet Protocol Television) is a system where a digital television
service is delivered via Internet Protocol over a network infrastructure,
which includes delivery by a broadband connection.
IP TV system includes unicasting/multicasting system of pay
satellite channels, video on demand, music on demand, video
clips, advertising center and supporting services.
1.3 REFERENCE CODES AND STANDARDS
All works including Equipment, workmanship and
installations shall be performed in strict accordance with the
drawings, specifications and latest stipulations of:
- Egyptian Electrical Standard
- EIA/TIA 568 B Performance specification for 4- pair
100 ohm category 6 cabling.
- EIA/TIA 569 Commercial building telecommunications
pathways and spaces.
- EIA/TIA 606 Administration standard for the
telecommunication infra-structure of commercial
buildings.
- EIA/TIA 607 Commercial building grounding and
bonding requirements for telecommunication.
- EIA/TIA-TSB72 Centralized Optical fiber cabling
guidelines.
- EIA/TIA ¡VTSB75 Additional horizontal cabling
practices for open offices
- EIA/TIA-526 Fiber optic system
- The relevant Egyptian Building Codes
- Egyptian safety Standard
- Standards of local authorities having jurisdiction
- All System components should pass the tests as
3
mentioned in the standards.
- Certificate of these testes should be submitted.
The engineer may accept other equivalent international
standards according to a written instruction.
1.4 Submittals
Submit the following in accordance with Conditions of the
Contract and Division-1 Specification Sections:
General: Submit complete sets of documentation as stated by
the contract conditions indicating type, size, rating, style,
catalog number, manufacturer's names, photographs and/or
catalog data sheets for all items to ensure compliance with
Specifications.
This documentation shall be subject to the approval of the
Engineer and no equipment shall be ordered without this
approval for all equipment and devices, which are shown on
Drawings and in Bill of Quantities.
Shop Drawings: Provide shop drawings showing equipment
and device locations and connecting wiring of entire television
distribution system, including riser diagrams.
Shop drawings shall include, but not be limited to, the
following:
- Complete one-line riser diagram(s)
- Pin to pin connection diagram.
- Provide calculations to support type of cables, system
gain and overall signal loss, in all cable routes from
start to end including network accessories, in order to
prove the adequacy of the proposed equipment to
provide signal strength at outlets.
- Include instructions and installation manuals.
- Complete sequence of operations and functions of the
system.
- Complete system blocks diagrams.
- A listing of the manufacturer's authorized local
representative responsible for installation coordination
and service.
Product Data: Submit manufacturer's technical product data,
including specifications and installations for each type of
equipment. Include standard or typical riser and wiring
diagrams, operation and maintenance instructions for
inclusion in maintenance manual.
4
Operation and Maintenance Data: Submit operation and
maintenance data and parts lists for each type of equipment
installed, including furnished specialties and accessories, and
circuit diagrams. Include this data, product data, and shop
drawings in operation and maintenance manual; in accordance
with requirements of Division-1 and other relevant
documentation.
1.5 QUALITY ASSURANCE
Manufacturer Qualifications: Manufacturing firms of IPTV
system shall be regularly engaged in manufacturing IP
Television Distribution Systems of type, size and
characteristics similar to those required by the Contract for
this project and whose products have been in satisfactory
service in similar projects for not less than two (2) years.
Installer Qualifications: Engage an experienced installer
who is a factory-authorized sales and service representative to
perform the work of this section. The installer firm shall have
at least five (5) years of successful installation experience of
TV distribution projects, with at least one project similar the
IPTV required for this project.
Training: Equipment¡¦s manufacturer and his authorized, local
representative shall provide, in depth, equipment service and
programming on site training to selected Employer¡¦s
personnel for one week.
1.6 DELIVERY, STORAGE AND HANDLING
Deliver products in factory original, unopened containers.
Store in clean, dry and shaded space in original containers.
Handle carefully to avoid damage.
1.7 RELATED SECTIONS
The following sections include requirements, which relate to
this section:
16050 General Electrical Materials and Methods.
16139 Cable Trays
1.8 AS-BUILT DRAWINGS
The Contractor shall put in writing all his remarks, during the
progress of work, concerning any suggested alterations from
the shop drawings in wiring routes, locations of equipment or
devices which arise from coordination between the system and
other activities.
- No execution of alterations is allowed before receiving
written approval from the Engineer.
5
- All alterations shall be registered and filled by the
Contractors and extra copies shall be submitted to the
involved parties (Engineer, Project manager, Site, etc.).
A complete as-built draft set of drawings and equipment
schedules shall be prepared 15 days after completion of work
for approval of the Engineer.
The draft As-built shall include all previously approved
alterations.
PART 2 PRODUCTS
2.1 GENERAL
IPTV is received by the viewer through the technologies used for
computer networks.IPTV is often provided in conjunction with Video on
Demand and may be bundled with Internet services such as Web access
and VoIP. IPTV shall be supplied using the closed network infrastructure
(corporate LAN).
Using set-top boxes at end users, TV channels shall be streamed to users
more efficiently than current coaxial cable.
Prefer separate switch for IPTV system .
Network shall allow higher speeds and multiple high definition TV
channels.
IPTV also allows significant opportunities to make the TV viewing
experience more interactive and personalized. The system may include an
interactive program guide that allows viewers to search for content by title
or actor¡¦s name, or a picture-in-picture functionality that allows them to
¡§channel surf¡¨ without leaving the program they¡¦re watching.
System may also include Video on Demand (Void) service allowing a
customer to browse an online movie catalogue, to watch trailers and to
select the movie he wants to watch.
2.2 EQUIPMENT AND MATERIALS
As with a digital satellite television system, an IPTV service
requires a video head end. This is the point in the network at
which broadcast TV and video on demand content is captured
and formatted for distribution over the IP
A head end takes each individual channel and encodes it into a
digital video format, like MPEG 4 which is the most prevalent
encoding standard for digital video.
After encoding, each channel is encapsulated into IP and sent
out over the project Local Area Network (LAN).User shall
6
install set top box before routing TV channels into his TV
receiver, or can use PC screen directly.
These channels are typically IP Unicast in which only the
selected channel(s) are distributed to the individual connected
users. Also multicast streams could be sent such as
advertisement broadcast service for lobbies, food courts and
open areas.
The IP TV services cabinet will be located in the satellite
headend in the project data center.
IPTV system is made up of following major elements:-
- Satellite and terrestrial reception Head End:-
- Streamer
- Encoder to encode channels to (Pay TV).
- Layer 3 switch and Gigabit Ethernet switch
- Access Network(By others)
- User network(By others)
- System management
N.B: contractor has to co-ordinate with project Local Area
Network for integration.
2.3 System Features
- Easy to use PC based interface
- Auto scheduling
- Auto formatting
- Auto multiple bit rate encoding
- Viewer GUI (graphic user interface)
- Fully customizable - to fit corporate broadcasting look
- Full controls for the viewer
- Manual and automatic viewer adjustments
- Set top box integration
- Full reporting - audience and media reports - over 180
full - real time reports
- Program Management to create programs from multiple
packages such as an Identification, Content,
Advertising.
- Advertising insert manager
- Video on Demand creation and serving
- Delivery to multiple targets and multiple delivery
speeds from Mobile to Set Top Box at high bit rates on
private multicast networks.
7
- Payment Gateway for Daily, Weekly, Monthly, Annual
for channels and programs
- Subscription management.
Receiving Dishes
Group of receiving dishes three (3) shall be used.
Dish Antennas shall be constructed of light aluminum alloy
with positive locking of all elements in position. All mounting
and fixing materials shall be protected against corrosion by
heavy anodic coating or corrosion resisting compound.
The antennas shall be fixed to a mast mounted on the roof of
the building. Masts shall be heavy-duty hot dipped galvanized
steel securely fixed to the roof so as to ensure resistance to the
strongest winds encountered in the locality.
Dish antennas shall comprise of the following minimum
specification:
Mount with Azimuth/Elevation adjustment
1.2m Fixed C/Ku solid Antenna
Dish Diameter 120cm
Focal Length 33 (68.2cm)
F/D Ratio 0.37
Frequency Range 1.0 ~ 12.75 GHz
Gain at 4.2 GHz 36 dBi
Gain at 12.2 GHz 44.9 dBi
Efficiency 70%
Reflector Material Galvanized Steel
Finish Electrostatic Power
Coating
Feed Prime Focus
Mount Polar
Max Wind Speed 90 Km (Operational)
LNB Converters
LNB shall comprise of the following minimum specification:
Band: Ku
No. of Inputs: 4
8
Polarity: V-Hi, V-Lo, H-Hi, HLo
Freq.Range Low band:10.7~11.7
GHz
Highband: 11.7~12.75 GHz
Noise Figure at 20Deg. C: 0.3
Input VSWR: 2.5:1
Input RF level: -100 to -55 dBm
Image Rejection Ratio: 45dB
Output Frequency: Low band:950-1450
MHz
High band: 1100-2150 MHz
Power Gain: 56~65 dB
Output Impedance: 75 ohms
Operating Temperature: -40Deg.C to + 50Deg.C
Relative Humidity: 100%
VHF/UHF Multi-band Antenna
Elements VHF/UH
F, UHF
(48)
VHF UHF
Reception
Range/Channels
E5-12 21-69
L05-10
174-230
MHZ
470-
862
MHZ
Maximum Gain ¡V
dB
10 15
Back/Front Ratio -
dB
22 220
Half Power Beam
Horizontal
49o 38o
Wind Loading 260 260
Cable Connection 75/300 Ohm
9
HEADEND Equipment
Programmable modular IP-Streamer units for Digital Satellite
Free-to-Air channels shall be used in the head end equipment
in addition to one Satellite Multiplexer unit for each four
Satellite Signal inputs.
IP GENERAL SPECIFICATIONS
Products REE Channels encrypt Encode
Total Streams 10TV 20TV 1 analogue
Clear Streams 10 20 NA
Encrypted Str. 0 20 NA
Transponders 2 4
Technical Parameters
System Linux
Network 100 Base-T Ethernet interface
Output format MPEG2 Transport Stream (TS) over UDP
Output bandwidth50 Mbit/s Average (10 TV Channels)
Multiplexing/ ISO/IEC 13818-1 and ETSI 300 468 compliant
Networking protocols Unicast & multicast with IPv4 or IPv6 protocols
Format DVB
Modulation QPSK
Technical Specifications
FREE/MXC/MXP ENC
QPSK demodulator MPEG2 encoder
LNB F type input Composite RCA and SVIDEO input
C & Ku band support Formats :PAL/SECAM
RF input level: -65 to -25 dBm MPEG2 format:720x576
25 pictures/sec; 24 bits
input frequency: 950 to 2150 MHz
Symbol rate: 1 to 45 MS/s, SCPC and MCPC support
Supports LNB 14/18V / OFF max 400 mA; 22 KHz,
band switch control (DiSEqC 1.0)
Size: 2U Rack
Power 100-220V/50 Hz
10
Decryption
Only for IP Stream MXC and MXP
Decryption methods for VIAACCESS, MEDIAGUARD, CRYPTOWORKS,
IRDETO
Support for PCMCIA Consumer modules allowing for the decryption of 4 ES
i.e. 2 TV streams (IP stream CS-MXC)
Support for PCMCIA Professional modules allowing for the decryption of 20
ES, i.e. 10 TV Streams (IP Stream CS-MXP)
Software
The Contractor shall comply with the following requirements
for all software related to all parts of the project:
- Contractor shall supply original software media. No
copies shall be accepted or installed at any time.
- Contractor shall supply original software licenses from
software supplier. No licenses issued by the contractor
shall be accepted.
- All software license agreements shall be in the name of
The Commercial Real Estate Company.
- Configuration: It is recommended that if changes are
required, to be done
- Through software configuration and not customization
or new development.
- In case the contractor chooses to offer specific feature
through new software
Development. The contractor must provide the software media
for all customized software if any.
IP-Stream: Broadcasts digital streams without signal recompression decryption of
encrypted steams
IP-Supervisor: Web Interface for stream monitoring
IP-Admin: Web Interface for the management of TV and radio
channel specifications.
Distribution System
The system shall comprise of the following items
A. COAXIAL
CABLES
Inner Conductor 1.13 mm
11
Characteristic Impedance 75+3 Ohms
Max. Attenuation (20 „a C): 14.6 dB/100m
(at 600 MHz)
Screen:
Copper/Aluminum Foil and
tinned copper
braid
Screening Efficiency >90 dB
Dielectric: Foam
Polyethylene
Loop Resistance Ohm/Km. 30.5
Propagation Factor 0.85
Cable Connectors
75 ohms connectors, joining connectors, Coaxial cables,
Outdoor Splitters
IP Distribution
IP Streams will utilizes the Data Network to transport the
streams from IP headend system to Interactive cards (STB) at
end users.
12
Grounding: To prevent accumulation of static charge on
antenna supporting structure, it shall be grounded by
connecting a heavy ground wire to the system earth (metal
stake driven into the earth). Grounding of the mast is also
essential.
Accessories: The cable networks shall include all necessary
accessories.
All accessories shall operate at the system frequency range
which covers the required band of frequencies.
Accessories shall have the minimum gain loss and shall
provide sufficient isolation on return loss characteristics.
PART 3 EXECUTION
3.1 EXAMINATION
Examine areas and conditions under which Television
Distribution System shall be installed. Do not proceed with
work until unsatisfactory conditions have been corrected in a
manner acceptable to the Engineer.
3.2 INSTALLATION OF BASIC IDENTIFICATION
Install electrical identification in accordance with
requirements of Section 16050 "Basic Electrical Materials and
Methods".
3.3 INSTALLATION OF BASIC WIRING SYSTEM
MATERIALS
Install wiring, raceways or conduits electrical boxes, cables
and fittings in accordance with Section 16100 "Raceways,
Boxes and Cabinets¡¨.
Install wiring of signal circuits and power limited circuit in
raceways or conduit or exposed on wall or ceilings when
properly protected. Use conduits for runs through floors or in
shaft ways to a height of 2.3 m above floor.
Install cables using special stripping tools which do not harm shields
and insulators. Use special gripping tools and do not use solder type
fittings and connectors.
3.4 INSTALLATION OF TELEVISION DISTRIBUTION
SYSTEM
Installation of equipment and devices that pertain to other
work of the Contract shall be closely coordinated with the
appropriate trade.
13
Equipment manufacturer shall provide all necessary assistance
to his authorized, local representative to:
- Coordinate the selection of system equipment.
- Execute field strength tests for all frequency bands to be
received by the system (VHF, UHF, Ku, C, etc..) .
- Perform complete functional tests of the system at all
outlets including signal strength, reflection coefficient, etc.
- Submit a written report attesting the proper operation of the
completed system.
Install Television Distribution System as indicated on
Drawings in accordance with equipment manufacturer's
written instructions and comply with the standards of
installation.
Complete wiring in accordance with manufacturer's
requirements. Color code wiring and install per
manufacturer's point-to-point wiring diagram. Determine
exact number of wires for each device installed.
Connect each device with sufficient wiring to complete its intended
operation.
Where there are number of power requiring devices, provide
extra or larger size wiring to alleviate voltage drops which
makes device operate beyond voltage limits for which it was
designed.
Determine above with manufacturers representative while
equipment is being installed.
Submit a signed copy of test results in duplicate to the
Engineer.
Equipment cabinets shall be installed in a special room for the
Television Distribution System and shall be arranged to
permit easy servicing of the different parts.
Cable bearers shall be installed on walls wherever needed.
Wall mounted equipment shall be installed according to the
manufacturer recommendations.
Power supply distribution board shall be installed in an
arrangement, which does not affect the safety of equipment
and cause no interference with the telecommunication system.
Air-conditioning shall be provided to the room if the
Television Distribution System stable operating conditions
and design considerations, stated by the manufacturer, require.
14
Fresh air supply to the room shall be highly filtered to prevent
the dust from entering equipment.
Powerful and even distributed illumination for the room of the
switching equipment shall be provided to permit easy view of
all components.
Equipment room shall be fitted with dustproof doors and
windows.
Ambient conditions shall be considered in the design of this
room.
3.5 FIELD QUALITY CONTROL
Connection and Supervision: Make connections to equipment
panel under manufacturer's supervision. Complete
connections between cabinets and panels utilizing
Manufacturer's technicians.
System Test and Approval: Submit shop drawings for
function and operation only, pre-approved by the Engineer.
- Prior to final acceptance of the system, the manufacturer of
system shall, in presence of the Contractor, Employer's
representative and Engineer's representative, test each
extension device.
END OF SECTION 16785

No comments: