C O O L I N G C A P A C I T Y

C O O L I N G C A P A C I T Y
M O D E L S AT 2 2 4 - 0 1 8 T O 4 2 4 - 9 3 6
Cooling capacity in l/s

EWT 32 36 32 36 32 36 32 37 35 40 35 40 35 37 40 42 36 37 41 42
MODEL LWT 27 26 27 26 27 26 27 27 30 30 30 30 30 32 30 32 31 32 31 32
NO. WB 19 19 20 20 21 21 22 22 24 24 25 25 26 26 26 26 27 27 27 27
AT 224 - 018 293 162 270 147 243 130 214 138 281 181 251 164 217 308 143 203 228 278 151 184
AT 224 - 118 306 172 283 156 256 138 225 146 294 191 264 173 228 322 152 214 240 291 160 194
AT 224 - 218 312 184 290 168 264 150 235 158 300 203 272 185 238 327 164 224 249 297 172 206
AT 224 - 318 334 191 310 174 281 155 248 164 321 212 289 193 251 350 169 236 264 317 179 215
AT 224 - 418 328 195 305 179 278 160 248 169 316 215 286 197 251 343 174 237 262 313 183 218
AT 224 - 518 338 209 314 193 288 176 258 184 325 227 296 210 262 354 189 248 272 322 197 230
AT 224 - 618 358 217 334 199 305 180 273 189 345 237 314 218 276 376 195 261 288 342 204 241
AT 224 - 718 383 234 357 216 327 195 293 205 369 256 336 235 297 402 211 281 309 366 220 259
AT 224 - 818 399 247 372 230 340 211 306 220 385 269 350 249 309 N.A. 225 293 322 381 235 272
AT 224 - 918 N.A. 257 386 239 353 219 318 228 400 279 363 259 321 N.A. 234 305 335 396 244 282
AT 424 - 024 371 204 342 184 308 162 270 173 356 228 318 206 274 391 179 256 288 352 189 232
AT 424 - 124 401 225 371 204 335 180 294 191 385 250 346 227 299 422 198 280 314 381 209 254
AT 424 - 224 396 232 368 211 335 189 297 199 381 256 345 233 301 416 206 284 315 378 217 260
AT 424 - 324 428 243 396 221 358 196 316 208 411 270 370 245 321 449 215 301 337 407 227 274
AT 424 - 424 429 255 399 234 364 210 325 220 413 281 375 257 329 450 228 310 344 409 240 285
AT 424 - 524 450 258 417 236 379 210 335 222 432 286 390 261 340 472 229 319 356 428 242 291
AT 424 - 624 441 272 411 252 376 230 338 240 425 296 386 274 342 462 247 324 356 421 258 300
AT 424 - 724 460 276 428 254 391 229 350 241 443 303 402 278 354 482 248 334 369 438 260 308
AT 424 - 824 487 295 453 272 414 246 371 257 469 323 426 297 376 510 265 355 392 464 278 328
AT 424 - 924 541 335 504 312 461 286 414 298 521 364 474 338 419 N.A. 306 397 437 516 318 369
AT 424 - 036 538 292 495 264 444 230 389 246 515 328 459 295 394 567 256 369 415 509 271 333
AT 424 - 136 566 312 522 281 469 248 412 264 542 348 485 315 418 596 273 390 439 536 289 354
AT 424 - 236 604 354 562 323 511 289 454 305 582 391 526 357 460 634 315 433 481 576 331 397
AT 424 - 336 646 368 599 334 542 297 478 314 621 408 559 371 485 679 325 455 509 615 343 414
AT 424 - 436 636 376 591 344 539 309 480 325 612 415 554 379 486 666 335 458 508 606 353 421
AT 424 - 536 655 404 610 374 558 341 501 356 631 440 573 407 507 686 366 480 528 625 382 445
AT 424 - 636 695 418 648 384 591 346 529 364 670 459 608 421 536 729 375 506 559 663 393 466
AT 424 - 736 744 452 693 417 633 376 568 394 717 495 651 455 575 779 407 543 599 710 426 501
AT 424 - 836 775 480 722 446 660 409 593 426 746 521 678 483 600 812 437 569 625 739 455 527
AT 424 - 936 805 499 750 464 685 425 616 443 775 541 705 502 623 N.A. 454 591 649 768 473 548
Note: For alternate selections and conditions other than those stated, consult your EVAPSPEC II selection program or local EVAPCO representative.
MODELS: AT 19-56 to 19-98
Weights (kg) Dimensions (mm)
Heaviest Fan
MODELS: AT 19-56 to 19-98
Weights (kg) Dimensions (mm)
Heaviest Fan Air
Model Nominal Section Motor Flow
No. Tons* Shipping Operating (Lower) (kW) (m3/s) H¢Ó B P L
AT 19-56 109 1315 2240 675 4.0 12.5 3026 1797 1965 1826
AT 19-66 120 1335 2260 675 5.5 14.3 3026 1797 1965 1826
AT 19-76 135 1425 2350 765 5.5 14.0 3331 2102 2270 1826
AT 19-86 148 1440 2365 765 7.5 15.3 3331 2102 2270 1826
AT 19-96 169 1570 2495 865 11.0 17.2 3636 2397 2578 1826
AT 19-28 133 1490 2585 770 4.0 14.8 3077 1848 2016 2283
AT 19-38 144 1505 2605 770 5.5 16.8 3077 1848 2016 2283
AT 19-48 156 1520 2615 770 7.5 18.5 3077 1848 2016 2283
AT 19-58 162 1610 2710 875 5.5 16.6 3381 2152 2320 2283
AT 19-68 175 1625 2720 875 7.5 18.1 3381 2153 2321 2283
AT 19-78 183 1745 2845 1,000 7.5 17.9 3686 2457 2626 2283
AT 19-88 193 1650 2750 875 11.0 20.6 3381 2153 2321 2283
AT 19-98 204 1775 2870 1,000 11.0 20.3 3686 2457 2626 2283
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
¢Ó Height includes fan guard which ships factory mounted.
. Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95¡ÆF to 85¡ÆF with a 78¡ÆF entering wet bulb temperature.
Swing Out Radius of Motor Cover
.
E N G I N E E R I N G D A T A & D I M E N S I O N S
10
E N G I N E E R I N G D A T A & D I M E N S I O N S
MODELS: AT 18-49 to 18-914
Weights (kg) Dimensions (mm)
Heaviest Fan Air
Model Nominal Section Motor Flow
No. Tons* Shipping Operating (Lower) (kW) (m3/s) H¢Ó B P L N S&Q
AT 18-49 186 1740 2960 935 7.5 19.4 3588 2245 2438 2731 460 1365
AT 18-59 191 1660 2880 840 11.0 22.5 3283 1940 2134 2731 460 1365
AT 18-69 214 1775 2995 935 11.0 22.0 3588 2245 2438 2731 460 1365
AT 18-79 222 1900 3120 1060 11.0 21.7 3893 2550 2743 2731 460 1365
AT 18-89 231 1795 3015 935 15.0 24.2 3588 2245 2438 2731 460 1365
AT 18-99 240 1925 3145 1060 15.0 23.7 3893 2550 2743 2731 460 1365
AT 18-511 209 1980 3395 1065 7.5 22.0 3588 2245 2438 3188 565 1594
AT 18-611 237 1905 3320 970 15.0 27.8 3283 1940 2134 3188 565 1594
AT 18-711 251 2165 3580 1215 11.0 24.5 3893 2550 2743 3188 565 1594
AT 18-811 264 2035 3450 1065 15.0 27.3 3588 2245 2438 3188 565 1594
AT 18-911 275 2185 3600 1215 15.0 26.8 3893 2550 2743 3188 565 1594
AT 18-312 232 2195 3845 1185 7.5 24.5 3588 2245 2438 3651 454 1826
AT 18-412 252 2360 4010 1345 7.5 24.0 3893 2550 2743 3651 454 1826
AT 18-512 263 2100 3750 1065 15.0 31.0 3283 1940 2134 3651 454 1826
AT 18-612 293 2250 3900 1185 15.0 30.4 3588 2245 2438 3651 454 1826
AT 18-712 307 2415 4065 1345 15.0 29.9 3893 2550 2743 3651 454 1826
AT 18-812 310 2265 3915 1185 18.5 32.7 3588 2245 2488 3651 454 1826
AT 18-912 323 2425 4080 1345 18.5 32.1 3893 2550 2743 3651 454 1826
AT 18-214 285 2430 4370 1335 11.0 30.4 3699 2356 2550 4261 302 2130
AT 18-314 306 2615 4555 1520 11.0 29.9 4004 2661 2854 4261 302 2130
AT 18-414 308 2295 4230 1160 18.5 36.3 3394 2051 2245 4261 302 2130
AT 18-514 315 2455 4390 1335 15.0 33.2 3699 2356 2550 4261 302 2130
AT 18-614 335 2640 4575 1520 15.0 32.7 4004 2661 2854 4261 302 2130
AT 18-714 342 2470 4405 1335 18.5 35.6 3699 2356 2550 4261 302 2130
AT 18-814 357 2475 4415 1335 22.0 37.8 3699 2356 2550 4261 302 2130
AT 18-914 374 2665 4600 1520 22.0 37.1 4004 2661 2854 4261 302 2130
Swing Out Radius of Motor Cover
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
¢Ó Height includes fan guard which ships factory mounted.
. Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95¡ÆF to 85¡ÆF with a 78¡ÆF entering wet bulb temperature.
.
2388
11
12
E N G I N E E R I N G D A T A & D I M E N S I O N S
MODELS: AT 28-518 to 28-921
Swing Out Radius of Motor Cover
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
¢Ó Height includes fan guard which ships factory mounted.
. Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95¡ÆF to 85¡ÆF with a 78¡ÆF entering wet bulb temperature.
.
Weights (kg) Dimensions (mm)
Heaviest Fan Air
Model Nominal Section Motor Flow
No. Tons* Shipping Operating (Lower) (kW) (m3/s) H¢Ó B P L N S Q
AT 28-518 367 3545 6070 2075 (2) 5.5 35.2 4105 2762 2956 5486 451 2743 1365
AT 28-618 384 3130 5650 1610 (2) 11.0 45.4 3496 2153 2346 5486 451 2743 1365
AT 28-718 432 3350 5875 1835 (2) 11.0 44.5 3800 2457 2651 5486 451 2743 1365
AT 28-818 467 3375 5895 1835 (2) 15.0 48.8 3800 2457 2651 5486 451 2743 1365
AT 28-918 485 3615 6135 2075 (2) 15.0 48.0 4105 2762 2956 5486 451 2743 1365
AT 28-521 423 3790 6765 2065 (2) 7.5 44.2 3800 2457 2651 6401 565 3200 1594
AT 28-621 450 4070 7040 2340 (2) 7.5 43.5 4105 2762 2956 6401 565 3200 1594
AT 28-721 478 3590 6565 1810 (2) 15.0 56.0 3496 2153 2346 6401 565 3200 1594
AT 28-821 532 3845 6815 2065 (2) 15.0 55.0 3800 2457 2651 6401 565 3200 1594
AT 28-921 554 4125 7095 2340 (2) 15.0 54.0 4105 2762 2956 6401 565 3200 1594
2388
1343
13
E N G I N E E R I N G D A T A & D I M E N S I O N S
MODELS: AT 28-524 to 28-928
Weights (kg) Dimensions (mm)
Fan Air
Model Nominal Heaviest Motor Flow
No. Tons* Shipping Operating Section (kW) (m3/s) H¢Ó B P L N S&Q M
AT 28-524 505 4710 8010 1345 (2) 7.5 47.9 4105 2762 2956 7366 454 1826 3651
AT 28-624 526 4190 7495 1065 (2) 15.0 61.7 3496 2153 2346 7366 454 1826 3651
AT 28-724 585 4490 7795 1180 (2) 15.0 60.6 3800 2457 2651 7366 454 1826 3651
AT 28-824 620 4520 7820 1180 (2) 18.5 65.0 3800 2457 2651 7366 454 1826 3651
AT 28-924 647 4845 8145 1345 (2) 18.5 63.9 4105 2762 2956 7366 454 1826 3651
AT 28-428 570 4890 8765 1345 (2) 11.0 61.7 3953 2610 2804 8586 302 2130 4261
AT 28-528 616 4620 8490 1175 (2) 18.5 73.8 3648 2305 2499 8586 302 2130 4261
AT 28-628 684 4960 8835 1345 (2) 18.5 72.4 3953 2610 2804 8586 302 2130 4261
AT 28-728 713 4980 8855 1345 (2) 22.0 76.8 3953 2610 2804 8586 302 2130 4261
AT 28-828 718 5335 9210 1535 (2) 18.5 71.2 4258 2915 3108 8586 302 2130 4261
AT 28-928 748 5350 9225 1535 (2) 22.0 75.4 4258 2915 3108 8586 302 2130 4261
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
Unit can operate as two (2) independent cells with the addition of a flume plate or water tight partition.
¡°M¡± dimension is identical for both cells.
¢Ó Height includes fan guard which ships factory mounted.
. Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95¡ÆF to 85¡ÆF with a 78¡ÆF entering wet bulb temperature.
Swing Out Radius of Motor Cover
.
2388
E N G I N E E R I N G D A T A & D I M E N S I O N S
MODELS: AT 38-236 to 38-942
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
Unit can operate as three (3) independent cells with the addition of a flume plate or water tight partition.
¡°M¡± dimension is identical for both cells.
¢Ó Height includes fan guard which ships factory mounted.
. Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95¡ÆF to 85¡ÆF with a 78¡ÆF entering wet bulb temperature.
Swing Out Radius of Motor Cover
.
Weights (kg) Dimensions (mm)
Fan Air
Model Nominal Heaviest Motor Flow
No. Tons* Shipping Operating Section (kW) (m3/s) H¢Ó B P L N S&Q M
AT 38-236 620 6165 11120 1045 (3) 7.5 73.9 3648 2305 2499 11081 454 1826 3651
AT 38-336 696 6615 11565 1195 (3) 7.5 72.7 3953 2610 2804 11081 454 1826 3651
AT 38-436 757 7105 12055 1355 (3) 7.5 71.4 4258 2915 3108 11081 454 1826 3651
AT 38-536 789 6330 11280 1065 (3) 15.0 92.1 3648 2305 2499 11081 454 1826 3651
AT 38-636 794 6710 11660 1195 (3) 11.0 82.5 3953 2610 2804 11081 454 1826 3651
AT 38-736 878 6775 11730 1195 (3) 15.0 90.3 3953 2610 2804 11081 454 1826 3651
AT 38-836 930 6815 11770 1195 (3) 18.5 97.0 3953 2610 2804 11081 454 1826 3651
AT 38-936 970 7305 12260 1355 (3) 18.5 95.3 4258 2915 3108 11081 454 1826 3651
AT 38-442 829 7785 13595 1530 (3) 7.5 79.5 4258 2915 3108 12911 302 2130 4261
AT 38-542 924 6915 12725 1170 (3) 18.5 110.1 3648 2305 2499 12911 302 2130 4261
AT 38-642 1026 7430 13240 1345 (3) 18.5 108.0 3953 2610 2804 12911 302 2130 4261
AT 38-742 1070 7455 13270 1345 (3) 22.0 114.5 3953 2610 2804 12911 302 2130 4261
AT 38-842 1077 7990 13800 1530 (3) 18.5 106.2 4258 2915 3108 12911 302 2130 4261
AT 38-942 1112 8015 13825 1530 (3) 22.0 112.5 4258 2915 3108 12911 302 2130 4261
14
2388
E N G I N E E R I N G D A T A & D I M E N S I O N S
MODELS: AT 112-012 to 112-914
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
¢Ó Height does not include fan guard.
¢Ó¢Ó Fan Guard ships loose for field mounting.
. Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95¡ÆF to 85¡ÆF with a 78¡ÆF entering wet bulb temperature.
Weights (kg) Dimensions (mm)
Heaviest Fan Air
Model Nominal Section Motor Flow
No. Tons* Shipping Operating (Upper) (kW) (m3/s) H¢Ó T P B L N S&Q O
AT 112-012 325 3375 6190 2270 11.0 38.4 4128 2540 2496 1588 3651 454 1826 184
AT 112-112 355 3395 6215 2290 15.0 42.1 4128 2540 2496 1588 3651 454 1826 184
AT 112-212 382 3420 6235 2315 18.5 45.2 4128 2540 2496 1588 3651 454 1826 184
AT 112-312 396 3640 6460 2535 15.0 41.4 4432 2845 2800 1588 3651 454 1826 184
AT 112-412 406 3465 6280 2360 22.0 47.9 4128 2540 2496 1588 3651 454 1826 184
AT 112-512 415 3865 6680 2760 15.0 40.7 4737 ¢Ó¢Ó3150 3105 1588 3651 454 1826 184
AT 112-612 427 3665 6480 2560 18.5 44.4 4432 2845 2800 1588 3651 454 1826 184
AT 112-712 454 3710 6525 2605 22.0 47.0 4432 2845 2800 1588 3651 454 1826 184
AT 112-812 475 3935 6750 2825 22.0 46.2 4737 ¢Ó¢Ó3150 3105 1588 3651 454 1826 184
AT 112-912 509 4045 6865 2940 30.0 50.6 4737 ¢Ó¢Ó3150 3105 1588 3651 454 1826 184
AT 112-314 440 3750 7075 2550 22.0 52.1 4280 2540 2623 1740 4261 302 2131 216
AT 112-414 462 4020 7345 2815 18.5 48.3 4585 2845 2927 1740 4261 302 2131 216
AT 112-514 485 4255 7580 3055 18.5 47.5 4890 ¢Ó¢Ó3150 3232 1740 4261 302 2131 216
AT 112-614 492 4050 7375 2850 22.0 51.1 4585 2845 2927 1740 4261 302 2131 216
AT 112-714 517 4285 7610 3085 22.0 50.3 4890 ¢Ó¢Ó3150 3232 1740 4261 302 2131 216
AT 112-814 541 4170 7495 2965 30.0 56.0 4585 2845 2927 1740 4261 302 2131 216
AT 112-914 566 4405 7730 3200 30.0 55.0 4890 ¢Ó¢Ó3150 3232 1740 4261 302 2131 216
Access Door Swings Inside Unit
AT 112-012 thru 912
(1) 200 Inlet
(1) 200 Outlet
AT 112-314 thru 914
(1) 250 Inlet
(1) 250 Outlet
.
15
E N G I N E E R I N G D A T A & D I M E N S I O N S
MODELS: AT 112-018 to 112-920
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
¢Ó Height does not include fan guard.
¢Ó¢Ó Fan Guard ships loose for field mounting.
. Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95¡ÆF to 85¡ÆF with a 78¡ÆF entering wet bulb temperature.
.
Weights (kg) Dimensions (mm)
Heaviest Fan Air
Model Nominal Section Motor Flow
No. Tons* Shipping Operating (Upper) (kW) (m3/s) H¢Ó T P L N S&Q
AT 112-018 512 4705 8910 3090 18.5 61.2 4432 2540 2775 5486 337 2743
AT 112-118 540 4755 8960 3140 22.0 64.9 4432 2540 2775 5486 337 2743
AT 112-218 569 5060 9260 3445 18.5 60.2 4737 2845 3080 5486 337 2743
AT 112-318 602 5105 9310 3495 22.0 63.7 4737 2845 3080 5486 337 2743
AT 112-418 631 5445 9650 3830 22.0 62.7 5042 ¢Ó¢Ó3150 3385 5486 337 2743
AT 112-518 664 5225 9430 3610 30.0 69.7 4737 2845 3080 5486 337 2743
AT 112-618 695 5560 9765 3945 30.0 68.6 5042 ¢Ó¢Ó3150 3385 5486 337 2743
AT 112-718 714 5255 9455 3640 37.0 74.8 4737 2845 3080 5486 337 2743
AT 112-818 747 5590 9795 3975 37.0 73.5 5042 ¢Ó¢Ó3150 3385 5486 337 2743
AT 112-918 776 5640 9845 4025 45.0 77.9 5042 ¢Ó¢Ó3150 3385 5486 337 2743
AT 112-520 664 5215 9935 3490 37.0 78.1 4432 2540 2775 6096 311 3048
AT 112-620 717 5930 10645 4200 30.0 70.3 5042 ¢Ó¢Ó3150 3385 6096 311 3048
AT 112-720 745 5545 10265 3820 37.0 76.6 4737 2845 3080 6096 311 3048
AT 112-820 777 5955 10675 4225 37.0 75.3 5042 ¢Ó¢Ó3150 3385 6096 311 3048
AT 112-920 807 6005 10725 4275 45.0 79.8 5042 ¢Ó¢Ó3150 3385 6096 311 3048
Access Door Swings Inside Unit
16
E N G I N E E R I N G D A T A & D I M E N S I O N S
MODELS: AT 212-024 to 212-928
Weights (kg) Dimensions (mm)
Heaviest Fan Air
Model Nominal Section Motor Flow
No. Tons* Shipping Operating (Upper) (kW) (m3/s) H¢Ó T P B L N S&Q M O
AT 212-024 711 6775 12410 2290 (2) 15.0 84.3 4432 2540 2800 1892 7366 454 1826 3651 184
AT 212-124 724 7220 12855 2515 (2) 11.0 75.6 4737 2845 3105 1892 7366 454 1826 3651 184
AT 212-224 765 6820 12455 2315 (2) 18.5 90.4 4432 2540 2800 1892 7366 454 1826 3651 184
AT 212-324 791 7265 12900 2535 (2) 15.0 82.7 4737 2845 3105 1892 7366 454 1826 3651 184
AT 212-424 812 6915 12545 2360 (2) 22.0 95.8 4432 2540 2800 1892 7366 454 1826 3651 184
AT 212-524 853 7310 12945 2560 (2) 18.5 88.7 4737 2845 3105 1892 7366 454 1826 3651 184
AT 212-624 894 7755 13390 2780 (2) 18.5 87.3 5042 ¢Ó¢Ó3150 3410 1892 7366 454 1826 3651 184
AT 212-724 909 7405 13035 2605 (2) 22.0 93.9 4737 2845 3105 1892 7366 454 1826 3651 184
AT 212-824 950 7845 13480 2825 (2) 22.0 92.4 5042 ¢Ó¢Ó3150 3410 1892 7366 454 1826 3651 184
AT 212-924 1018 8075 13710 2940 (2) 30.0 101.1 5042 ¢Ó¢Ó3150 3410 1892 7366 454 1826 3651 184
AT 212-128 829 7430 14080 2515 (2) 18.5 98.4 4737 2540 3080 2197 8585 302 2131 4261 216
AT 212-228 858 7975 14625 2790 (2) 15.0 90.1 5042 2845 3385 2197 8585 302 2131 4261 216
AT 212-328 879 7495 14145 2550 (2) 22.0 104.2 4737 2540 3080 2197 8585 302 2131 4261 216
AT 212-428 923 8030 14680 2815 (2) 18.5 96.6 5042 2845 3385 2197 8585 302 2131 4261 216
AT 212-528 971 8500 15150 3055 (2) 18.5 95.1 5347 ¢Ó¢Ó3150 3689 2197 8585 302 2131 4261 216
AT 212-628 985 8090 14740 2850 (2) 22.0 102.3 5042 2845 3385 2197 8585 302 2131 4261 216
AT 212-728 1033 8565 15215 3085 (2) 22.0 100.6 5347 ¢Ó¢Ó3150 3689 2197 8585 302 2131 4261 216
AT 212-828 1081 8330 14980 2965 (2) 30.0 112.0 5042 2845 3385 2197 8585 302 2131 4261 216
AT 212-928 1133 8800 15450 3200 (2) 30.0 110.0 5347 ¢Ó¢Ó3150 3689 2197 8585 302 2131 4261 216
Access Doors
Swing Inside Unit
AT 212-024 thru 924
(2) 200 Inlets
(2) 200 Outlets
AT 212-128 thru 928
(2) 250 Inlets
(2) 250 Outlets
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
Unit can operate as two (2) independent cells with the addition of a flume plate or water tight partition. ¡°M¡± dimension is identical for both cells.
¢Ó Height includes fan guard which ships factory mounted.
¢Ó¢Ó Fan Guard ships loose for field mounting.
. Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95¡ÆF to 85¡ÆF with a 78¡ÆF entering wet bulb temperature.
.
17
18
E N G I N E E R I N G D A T A & D I M E N S I O N S
MODELS: AT 212-036 to 212-936
Weights (kg) Dimensions (mm)
Heaviest Fan Air
Model Nominal Section Motor Flow
No. Tons* Shipping Operating (Upper) (kW) (m3/s) H¢Ó T P
AT 212-036 1067 10190 18595 3420 (2) 15.0 112.1 5042 2845 3385
AT 212-136 1080 9625 18035 3140 (2) 22.0 129.8 4737 2540 3080
AT 212-236 1191 10905 19315 3780 (2) 18.5 118.5 5347 ¢Ó¢Ó3150 3689
AT 212-336 1203 10335 18740 3495 (2) 22.0 127.5 5042 2845 3385
AT 212-436 1262 11005 19415 3830 (2) 22.0 125.4 5347 ¢Ó¢Ó3150 3689
AT 212-536 1328 10570 18980 3610 (2) 30.0 139.5 5042 2845 3385
AT 212-636 1389 11240 19650 3945 (2) 30.0 137.2 5347 ¢Ó¢Ó3150 3689
AT 212-736 1427 10625 19035 3640 (2) 37.0 149.7 5042 2845 3385
AT 212-836 1495 11295 19705 3975 (2) 37.0 147.0 5347 ¢Ó¢Ó3150 3689
AT 212-936 1553 11395 19805 4025 (2) 45.0 155.7 5347 ¢Ó¢Ó3150 3689
Access Doors
Swing Inside Unit
.
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
Unit can operate as two (2) independent cells with the addition of a flume plate or water tight partition.
¢Ó Height does not include fan guard.
¢Ó¢Ó Fan Guard ships loose for field mounting.
. Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95¡ÆF to 85¡ÆF with a 78¡ÆF entering wet bulb temperature.
E N G I N E E R I N G D A T A & D I M E N S I O N S
MODELS: AT 312-036 to 312-942
((3) THREE-CELL COOLING TOWERS)
Access Doors
Swing Inside Unit
AT 312-036 thru 936
(3) 200 Inlets
(3) 200 Outlets
AT 312-042 thru 942
(3) 250 Inlets
(3) 250 Outlets
.
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
Unit can operate as three (3) independent cells with the addition of two flume plates or water tight partitions.
¢Ó Height does not include fan guard. ¢Ó¢Ó Fan Guard ships loose for field mounting.
. Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95¡ÆF to 85¡ÆF with a 78¡ÆF entering wet bulb temperature.
Weights (kg) Dimensions (mm)
Heaviest Fan Air
Model Nominal Section Motor Flow
No. Tons* Shipping Operating (Upper) (kW) (m3/s) H¢Ó T P B L N S&Q M O
AT 312-036 1080 10095 18545 2290 (3) 15.0 127.6 4737 2540 3105 2197 11081 454 1826 3651 184
AT 312-136 1098 10765 19215 2515 (3) 11.0 114.5 5042 2845 3410 2197 11081 454 1826 3651 184
AT 312-236 1161 10165 18615 2315 (3) 18.5 137.0 4737 2540 3105 2197 11081 454 1826 3651 184
AT 312-336 1200 10830 19280 2535 (3) 15.0 125.3 5042 2845 3410 2197 11081 454 1826 3651 184
AT 312-436 1256 11500 19950 2760 (3) 15.0 123.4 5347 ¢Ó¢Ó3150 3715 2197 11081 454 1826 3651 184
AT 312-536 1294 10900 19350 2560 (3) 18.5 134.4 5042 2845 3410 2197 11081 454 1826 3651 184
AT 312-636 1355 11565 20015 2780 (3) 18.5 132.2 5347 ¢Ó¢Ó3150 3715 2197 11081 454 1826 3651 184
AT 312-736 1377 11035 19485 2605 (3) 22.0 142.3 5042 2845 3410 2197 11081 454 1826 3651 184
AT 312-836 1439 11705 20155 2825 (3) 22.0 139.9 5347 ¢Ó¢Ó3150 3715 2197 11081 454 1826 3651 184
AT 312-936 1543 12045 20495 2940 (3) 30.0 153.2 5347 ¢Ó¢Ó3150 3715 2197 11081 454 1826 3651 184
AT 312-042 1199 12150 22125 2760 (3) 11.0 124.5 5347 2845 3689 2502 12910 302 2130 4261 216
AT 312-142 1259 11415 21390 2515 (3) 18.5 148.9 5042 2540 3385 2502 12910 302 2130 4261 216
AT 312-242 1267 12860 22835 3000 (3) 11.0 122.4 5652 ¢Ó¢Ó3150 3994 2502 12910 302 2130 4261 216
AT 312-342 1302 12235 22210 2790 (3) 15.0 136.3 5347 2845 3689 2502 12910 302 2130 4261 216
AT 312-442 1401 12315 22290 2815 (3) 18.5 146.2 5347 2845 3689 2502 12910 302 2130 4261 216
AT 312-542 1471 13025 22995 3055 (3) 18.5 143.9 5652 ¢Ó¢Ó3150 3994 2502 12910 302 2130 4261 216
AT 312-642 1493 12410 22385 2850 (3) 22.0 154.8 5347 2845 3689 2502 12910 302 2130 4261 216
AT 312-742 1565 13120 23090 3085 (3) 22.0 152.3 5652 ¢Ó¢Ó3150 3994 2502 12910 302 2130 4261 216
AT 312-842 1639 12765 22740 2965 (3) 30.0 169.5 5347 2485 3689 2502 12910 302 2130 4261 216
AT 312-942 1716 13470 23445 3200 (3) 30.0 166.5 5652 ¢Ó¢Ó3150 3994 2502 12910 302 2130 4261 216
19
20
E N G I N E E R I N G D A T A & D I M E N S I O N S
MODELS: AT 312-054 to 312-960
((3) THREE-CELL COOLING TOWERS)
Access Doors
Swing Inside Unit
AT 312-054 thru 960
(3) 250 Inlets
(3) 250 Outlets
.
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
Unit can operate as three (3) independent cells with the addition of two flume plates or water tight partitions.
¢Ó Height does not include fan guard.
¢Ó¢Ó Fan Guard ships loose for field mounting.
. Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95¡ÆF to 85¡ÆF with a 78¡ÆF entering wet bulb temperature.
Weights (kg) Dimensions (mm)
Heaviest Fan Air
Model Nominal Section Motor Flow
No. Tons* Shipping Operating (Upper) (kW) (m3/s) H¢Ó T P B L N S&Q M O
AT 312-054 1631 14640 27255 3140 (3) 22.0 194.8 5042 2540 3385 2502 16586 337 2743 5486 216
AT 312-154 1716 15555 28170 3445 (3) 18.5 180.6 5347 2845 3689 2502 16586 337 2743 5486 216
AT 312-254 1801 14995 27610 3255 (3) 30.0 213.4 5042 2540 3385 2502 16586 337 2743 5486 216
AT 312-354 1815 15705 28320 3495 (3) 22.0 191.3 5347 2845 3689 2502 16586 337 2743 5486 216
AT 312-454 1903 16710 29325 3830 (3) 22.0 188.3 5652 ¢Ó¢Ó3150 3994 2502 16586 337 2743 5486 216
AT 312-554 2003 16055 28670 3610 (3) 30.0 209.3 5347 2845 3689 2502 16586 337 2743 5486 216
AT 312-654 2095 17065 29680 3945 (3) 30.0 205.9 5652 ¢Ó¢Ó3150 3994 2502 16586 337 2743 5486 216
AT 312-754 2152 16140 28755 3640 (3) 37.0 224.6 5347 2845 3689 2502 16586 337 2743 5486 216
AT 312-854 2253 17145 29760 3975 (3) 37.0 220.6 5652 ¢Ó¢Ó3150 3994 2502 16586 337 2743 5486 216
AT 312-954 2341 17295 29910 4025 (3) 45.0 233.7 5652 ¢Ó¢Ó3150 3994 2502 16586 337 2743 5486 216
AT 312-260 1702 16465 30615 3625 (3) 18.5 184.3 5347 2845 3689 2502 18415 311 3048 6096 216
AT 312-360 1807 17690 31840 4030 (3) 18.5 181.3 5652 ¢Ó¢Ó3150 3994 2502 18415 311 3048 6096 216
AT 312-460 1980 16055 30210 3490 (3) 37.0 233.2 5042 2540 3385 2502 18415 311 3048 6096 216
AT 312-560 2045 16970 31120 3790 (3) 30.0 213.3 5347 2845 3689 2502 18415 311 3048 6096 216
AT 312-660 2139 18195 32345 4200 (3) 30.0 209.9 5652 ¢Ó¢Ó3150 3994 2502 18415 311 3048 6096 216
AT 312-760 2223 17050 31205 3820 (3) 37.0 228.6 5347 2845 3689 2502 18415 311 3048 6096 216
AT 312-860 2319 18275 32425 4225 (3) 37.0 224.9 5652 ¢Ó¢Ó3150 3994 2502 18415 311 3048 6096 216
AT 312-960 2408 18425 32575 4275 (3) 45.0 238.4 5652 ¢Ó¢Ó3150 3994 2502 18415 311 3048 6096 216
21
E N G I N E E R I N G D A T A & D I M E N S I O N
MODELS: AT 224-018 to 224-918
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
Unit can operate as two (2) independent cells with the addition of a flume plate or water tight partition.
¢Ó Height does not include fan guard.
¢Ó¢Ó Fan Guard ships loose for field mounting.
. Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95¡ÆF to 85¡ÆF with a 78¡ÆF entering wet bulb temperature.
Access Doors
Swing Inside Unit
Weights (kg) Dimensions (mm)
Heaviest Fan Air
Model Nominal Section Motor Flow
No. Tons* Shipping Operating (Upper) (kW) (m3/s) H¢Ó T P
AT 224-018 1023 9555 17960 3090 (2) 18.5 122.0 5042 2540 3385
AT 224-118 1080 9650 18060 3140 (2) 22.0 129.3 5042 2540 3385
AT 224-218 1137 10260 18670 3445 (2) 18.5 119.9 5347 2845 3689
AT 224-318 1193 9890 18300 3255 (2) 30.0 141.7 5042 2540 3385
AT 224-418 1203 10360 18770 3495 (2) 22.0 127.0 5347 2845 3689
AT 224-518 1262 11030 19440 3830 (2) 22.0 125.0 5652 ¢Ó¢Ó3150 3994
AT 224-618 1328 10595 19005 3610 (2) 30.0 138.9 5347 2845 3689
AT 224-718 1427 10650 19060 3640 (2) 37.0 149.1 5347 2845 3689
AT 224-818 1495 11320 19730 3975 (2) 37.0 146.4 5652 ¢Ó¢Ó3150 3994
AT 224-918 1553 11420 19830 4025 (2) 45.0 155.1 5652 ¢Ó¢Ó3150 3994
2502
22
E N G I N E E R I N G D A T A & D I M E N S I O N S
MODELS: AT 424-024 to 424-924
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
Unit can operate as two (2) independent cells with the addition of a flume plate or water tight partition.
¢Ó Height does not include fan guard.
¢Ó¢Ó Fan Guard ships loose for field mounting.
. Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95¡ÆF to 85¡ÆF with a 78¡ÆF entering wet bulb temperature.
Note: Unit ships with (2) two pans
and (4) fan/casing sections.
Access Door Swings
Inside Unit
AT 424-024 thru 924
(4) 200 Inlets
(2) 300 Outlets
.
Weights (kg) Dimensions (mm)
Heaviest Fan
MODELS: AT 424-024 to 424-924
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
Unit can operate as two (2) independent cells with the addition of a flume plate or water tight partition.
† Height does not include fan guard.
†† Fan Guard ships loose for field mounting.
✦ Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95°F to 85°F with a 78°F entering wet bulb temperature.
Note: Unit ships with (2) two pans
and (4) fan/casing sections.
Access Door Swings
Inside Unit
AT 424-024 thru 924
(4) 200 Inlets
(2) 300 Outlets

Weights (kg) Dimensions (mm)
Heaviest Fan Air
Model Nominal Section Motor Flow
No. Tons* Shipping Operating (Upper) (kW) (m3/s) H† T P L O Q
AT 424-024 1291 13415 24695 2270 (4) 11.0 152.3 5042 2540 3410 7360 251 1826
AT 424-124 1413 13510 24785 2290 (4) 15.0 167.0 5042 2540 3410 7360 251 1826
AT 424-224 1439 14395 25675 2515 (4) 11.0 149.8 5347 2845 3715 7360 251 1826
AT 424-324 1520 13600 24875 2315 (4) 18.5 179.2 5042 2540 3410 7360 251 1826
AT 424-424 1573 14490 25765 2535 (4) 15.0 164.0 5347 2845 3715 7360 251 1826
AT 424-524 1613 13780 25055 2360 (4) 22.0 189.9 5042 2540 3410 7360 251 1826
AT 424-624 1650 15375 26655 2760 (4) 15.0 161.4 5652 ††3150 4020 7360 251 1826
AT 424-724 1697 14580 25855 2560 (4) 18.5 175.8 5347 2845 3715 7360 251 1826
AT 424-824 1808 14760 26035 2605 (4) 22.0 186.2 5347 2845 3715 7360 251 1826
AT 424-924 2026 16105 27380 2940 (4) 30.0 200.4 5652 ††3150 4020 7360 251 1826
23
E N G I N E E R I N G D A T A & D I M E N S I O N S
MODELS: AT 424-036 to 424-936
NOTE: An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions are subject to change.
Connections larger than 80mm are Beveled for Welding (BFW) and grooved for a mechanical coupling.
Adequate spacing must be allowed for access to the cooling tower.
Unit can be arranged for cell operation. Consult the factory.
† Height does not include fan guard.
†† Fan Guard ships loose for field mounting.
✦ Outlet connection extends 10mm beyond bottom flange.
* Nominal tons are based on cooling 3 GPM per ton from 95°F to 85°F with a 78°F entering wet bulb temperature.
Note: Unit ships with (2) two pans
and (4) fan/casing sections.
Connections
this end for
Models AT 424-
036 thru 936.
Access Door Swings
Inside Unit
AT 424-036 thru 936
(4) 250 Inlets
(4) 250 Outlets

Weights (kg) Dimensions (mm)
Heaviest Fan Air
Model Nominal Section Motor Flow
No. Tons* Shipping Operating (Upper) (kW) (m3/s) H† T P L O Q
AT 424-036 1857 18780 35690 3255 (4) 15.0 218.9 5042 2540 3385 11030 216 2743
AT 424-136 1969 18870 35780 3255 (4) 18.5 235.3 5042 2540 3385 11030 216 2743
AT 424-236 2198 20285 37195 3445 (4) 18.5 231.4 5347 2845 3689 11030 216 2743
AT 424-336 2298 19540 36450 3255 (4) 30.0 273.3 5042 2540 3385 11030 216 2743
AT 424-436 2324 20485 37395 3495 (4) 22.0 245.0 5347 2845 3689 11030 216 2743
AT 424-536 2448 21825 38735 3830 (4) 22.0 241.1 5652 ††3150 3994 11030 216 2743
AT 424-636 2569 20955 37865 3610 (4) 30.0 268.1 5347 2845 3689 11030 216 2743
AT 424-736 2764 21065 37975 3640 (4) 37.0 287.6 5347 2845 3689 11030 216 2743
AT 424-836 2900 22405 39315 3975 (4) 37.0 282.6 5652 ††3150 3994 11030 216 2743
AT 424-936 3012 22605 39515 4025 (4) 45.0 299.5 5652 ††3150 3994 11030 216 2743
S
End Elevation
L
Models AT 112-012 through 312-960
Two “I” Beams Required (by Others)
Plan View
Dimensions (mm)
Model No. W L
AT 112-012 to 912 3607 3651
AT 112-314 to 914 3607 4261
AT 112-018 to 918 3607 5486
AT 112-520 to 920 3607 6096
AT 212-024 to 924 3607 7366
AT 212-128 to 928 3607 8585
AT 212-036 to 936 3607 11036
AT 312-036 to 936 3607 11081
AT 312-042 to 942 3607 12911
AT 312-054 to 954 3607 16586
AT 312-260 to 960 3607 18415
Dimensions (mm)
Model No. W L
AT 19-56 to 96 1826 2578
AT 19-28 to 98 2283 2578
AT 18-49 to 99 2388 2731
AT 18-511 to 911 2388 3188
AT 18-312 to 912 2388 3651
AT 18-214 to 914 2388 4261
AT 28-518 to 918 2388 5486
AT 28-521 to 921 2388 6401
AT 28-524 to 924 2388 7366
AT 28-428 to 928 2388 8585
AT 38-236 to 936 2388 11081
AT 38-442 to 942 2388 12911
Models AT 19-56 through 38-942
Two “I” Beams Required (by Others)
Notes:
Models AT 19-56 through 312-960
1. These are suggested arrangements for preliminary layout purposes. Consult your EVAPCO representative or http://www.evapcoeurope.com/ for
factory certified steel support drawings.
2. The recommended support for the AT Cooling Tower is structural “I” beams located under the outer flanges and running the entire length
of the unit. The unit should be elevated to allow access underneath the unit and to the roof below. Mounting holes, 19mm in diameter,
are located in the bottom flanges of the pan to provide for bolting to the structural steel.
3. Beams should be sized in accordance with accepted structural practices. Maximum deflection of beam under unit to be 1/360 of the unit
length, not to exceed 13mm.
4. For these models where two support beams are required, deflection may be calculated by using 55% of the operating weight as a uniform
load on each beam.
5. Beams should be level before setting the unit in place. Do not level the unit by shimming between it and the “I” beams.
6. Support beams and Anchor bolts are to be furnished by others.
7. Dimensions, weights and data are subject to change without notice. Refer to the factory certified drawings for exact dimensions.